Product Details:
Model Name/Number | 410 |
Brand | Leica |
Usage/Application | Industrial |
Range | up to 150 m |
Dimensions | 5.6 x 2.3 x 1.1 Inch |
Distance | 10,50,100 m |
Typical Measuring Accuracy | +- 1 mm |
Measurements per set of batteries | up to 5000 |
Batteries | Type AA 2 x 1.5 V |
Weight with Batteries | 198 g |
Product Details:
Brand | Hanna |
Dimensions | 221 X 115 X 55 mm |
Model Name/Number | HI9829 |
Weight | 750 g (26.5 oz.) |
Waterproof Protection | IP67 |
Temperature Compensation | -5 to 55 deg C (23 to 131 deg F) |
Logging Memory from Meter | Up to 60000 samples with 13 measurements each |
Logging Interval | 1 second to 3 hours |
Environment | 0 to 50 deg C (32 to 122 deg F); RH 100% |
Product Details:
Model Name/Number | HI 98100 |
Usage/Application | Laboratory |
Weight | 50 g (1.8 oz.) |
Environment | 0 to 50 deg C (32 to 122 deg F); RH 95 % max |
Brand | Hanna |
Range PH | 0.00 to 14.00 pH |
Resolution pH | 0.01 pH |
Accuracy pH | +- 0.2 pH |
Dimensions | 71 X 50 X 21 mm (2.8 X 2.0 X .77 Inch) |
Product Details:
Model Name/Number | HI 9565 |
Accuracy | +-3 % RH |
Weight | 340 g (12 oz.) |
Brand | Hanna |
Range | 20.0 to 95.0 % RH |
Resolution | 0.1 % RH / 0.1 deg C / 0.1 deg F |
Battery Type | 1 x 9 V |
Battery Life | 250 Hours of Continuous Use |
Environment | 0 to 60 DegreeC (32 to 122 DegreeF); 98% RH non-condensing |
Dimensions | 164 x 76 x 45 mm, (6.5 x 3.0 x 1.8 Inch) |
Product Details:
Weight | 420 g (14.8 oz.) |
Brand | Hanna |
Grade | Automatic |
Model Number | HI 96811 |
Sugar Content Range | 0 to 50 % Brix |
Temperature Range | 0 to 80 deg C (32 to 176 deg F) |
Sugar Content Resolution | 0.1 % Brix |
Temperature Resolution | +-0.1 deg C (0.1 deg F) |
Sugar Content Accuracy | +-0.2 % Brix |
Temperature Accuracy | +-0.3 deg C (0.5 deg F) |
Temperature Compensation | Automatic between 10 and 40 deg C (50 to 104 deg F) |
Enclosure Rating | IP65 |
Dimensions | 192 X 104 X 69 mm (7.6 x 4.1 x 2.7 Inch) |
Product Details:
Model Name/Number | HI 141 |
Measurement Parameters | Temperature |
Number of Input Channels | 2 Channels |
Maximum Temperature Measurement | +125 (Internal) deg C |
Power Source | Battery |
Best Temperature Measurement Accuracy | +- 0.4 deg C |
Display Type | LCD |
Dimensions | 86.5 (Dia.) x 35mm |
Temperature Measurement Rnesolutio | 0.1 deg C |
Number of Readings Per Channel | 16000 Channel |
Product Details:
Brand | Hanna |
Usage/Application | Laboratory |
Accuracy | +-1% of reading (+-0.01 uS/cm) |
Temperature Range | -20.0 to 120 deg C |
Weight | 1.2 Kg |
Cell Constant | 0.0500 to 200.00 |
Temperature Coefficient | 0.00 to 10.00%/ deg C |
Cell Type | 4 cells |
Reference Temperature | 5.0 to 30.0 deg C |
Power Supply | 12 V DC adapter |
Environment | 0 to 50 deg C RH max 95% non-condensing |
Dimensions | 160 X 231 X 94 mm |
The Hanna Research Grade Conductivity TDS Meter provides clear directions on how to perform each testing stage and automatically monitors the temperature, conductivity and stability during testing and determines whether a sample is within USP limits.
This instrument is equipped with auto standard recognition and can support custom calibration solutions. Up to a four point calibration can be obtained for enhanced accuracy over an extended measuring range.
The enhanced warning system is in place to alert users when measuring outside the calibration range. This system will also remind the user when a new calibration is due.
Features also include real-time graphic displays and on-screen GLP data. On-board contextual help can be accessed from any mode via the HELP button.
Up to 10 profiles can be saved and recalled eliminating the need to reconfigure each time when a different electrode is used.
Three selectable logging modes are available: Automatic, Manual and AutoHold logging. Up to 100 logging lots with 10,000 records per lot can be stored for automatic or manual modes along with up to 200 USP reports.
All features are available in English, Italian, Portuguese and Spanish. Connect to a PC via the USB or RS232 ports with the use of HI-92000 Windows compatible software.
Ideal:Product Details:
Brand | Hanna |
Model Name/Number | HI2300 |
Power Supply | 12 VDC adapter |
Temperature Accuracy | +-0.4 deg C |
Weight | 1.3 kg (2.9 lbs.) |
Dimensions | 235 x 222 x 109 mm (9.2 x 8.7 x 4.3 Inch) |
Environment | 0 to 50 deg C (32 to 122 deg F); RH max 95% |
Temperature Resolution | 0.1 deg C |
Product Details:
Model Name/Number | HI98703 |
Weight | 512 g (18 oz.) |
Display | 60 x 90 mm back lit LCD |
Dimensions | 224 x 87 x 77 mm (8.8 x 3.4 x 3.0 Inch) |
Environment | 0 to 50 deg C (32 to 122 deg F), RH max 95% non-condensing |
Power Supply | 4 (1.5V) AA Alkaline batteries or AC adapter |
Logging Memory | 200 Records |
Turbidity Accuracy | +-2% of reading plus 0.02 NTU |
Turbidity Resolution | 0.01; 0.1; 1 NTU |
Product Details:
Model Name/Number | HI88703 |
Weight | 2.5 kg (88 oz.) |
Accuracy | +-2% of reading plus 0.02 NTU (0.15 Nephelo; 0.01 EBC); +-5% of reading above 1000 NTU (6700 Nephelu |
Brand | Hanna |
Dimensions | 230 x 200 x 145 mm (9 x 7.9 x 5.7 Inch) |
Power Supply | 230/115 V AC ; 50/60 Hz; auto-off after 15 minutes of non-use |
Environment | 0 to 50 deg C (32 to 122 deg F); max 95% RH non-condensing |
Log Memory | 200 records |
Repeatability | +-1% of reading or 0.02 NTU (0.15 Nephelo; 0.01 EBC) which ever is greater |
Product Details:
Model Name/Number | HI 98303 |
Accuracy | +-2% FS |
Resolution | 1 uS/cm |
Weight | 95 g (3.4 oz.) |
Temperature Compensation | 0 to 50 deg C (32 to 122 deg F) |
Brand | Hanna |
Range | 1999 uS/cm |
Calibration Solution | HI 70031 |
Battery Type and Life | 1.5V (4) / approx. 200 hours of continuous use |
Environment | 0 to 50 deg C (32 to 122 deg F); RH max 95% non-condensing |
Dimensions | 175 x 41 x 23 mm (6.9 x 1.6 x 0.9 Inch) |
Product Details:
Model Name/Number | MX1101 |
Dimension | 3.66 x 8.48 x 2.29 cm (1.44 x 3.34 x 0.9 in.) |
Brand | Hobo |
Memory | 84,650 Measurements |
Battery Life | 1 Year, Typical With Logging Rate Of 1 Minute And Sampling Interval Of 15 Seconds Or Greater |
Resolution | 0.01%RH |
Sampling Rate | 1 Second to 18 hours, User Selectable |
Hysteresis | +-2% RH |
Range | 1% - 90% RH, non-condensing |
Response Time | 7.30 minutes in air moving 1 m/s (2.2 mph) |
Product Details:
Application | Laboratory |
Brand | HTC |
Dimension | 177 (H) x 98 (W) x 39 (D) mm |
Model Name/Number | AL-7010 |
Altimeter Metric | 500 ~ 9000 Meters |
Barometer Metric | 300 ~ 1100 hPa/mbar |
Indoor Temperature | -10 ~ 60 deg C |
Humidity | 20% ~ 90% Rh |
Stop Watch | 9 hr 59 min 59 sec |
Product Details:
Brand | Haga |
Material | Stainless Steel |
Frequency | 50 Hz |
Voltage | 4 V to 5.5 V |
Dimension | 14.5 X 17 X 2.5 cm |
Weight | 320 grams |
The 320 Grams Haga Altimeter for measuring tree heights, developed in 1950 by our company's founder Hans Haga, has been an essential tool in the international forestry and timber industry from back then to this day.
Combining precise functionality and comfortable handling with a long-life cycle, the altimeter became an unique product classic.
The indicator and scale systems are integrated into a rugged light metal casing and protected against outside influences. The pistol-shaped casing makes usage easy which is important for the accuracy of ongoing measurings.
The height determination is based on the known manner of measuring the angle between the altimeter's position and the top of the tree. The distance to an object can be measured comfortably and quickly and can even be improved with a rangefinder tape. Furthermore, the device is designed to support an optical rangefinder.
Auxiliary Equipment:
Product Details:
Model Name/Number | HI935005 |
Product Type | K Type |
Brand | Hanna |
Material | ABS Plastic |
Accuracy | 0.2 % |
Range | -50.0 to 199.9 deg C; 200 to 1350 degC |
Resolution | 0.1 deg C (-50.0 to 199.9 deg C); 1 degC |
Battery Type | 3 x 1.5 V AA / approx |
Environment | -10 to 50 deg C (14 to 122 deg F); RH max 100% |
Dimensions | 150 X 80 X 36 mm (5.9 x 3.1 x 1.4 Inch) |
Weight | 235 g (8.3 oz.) |
Maintenance and awareness are the first lines of defence in the battle against legionella. Supporting operators in this battle, the Hanna HI-935005 delivers highly accurate temperature measurements across a wide range using a K-type thermocouple probe. Display showing minimum and maximum temperature values taken during the measuring session helps with comprehensive record taking. Used regularly in applications where warm or hot water is converted into droplet or steam formation, the high accuracy HI-935005 can help to prevent the risk of Legionella by ensuring that temperatures are high enough in the water system to destroy the bacteria.
Product Details:
Model Name/Number | HI839800 |
Connectivity | USB |
Range | Up to 1000 NTU |
Display | 40 x 70 mm Graphic LCD |
Application | Industrial |
Weight | 512 g |
Brand | Hanna |
Product Details:
Minimum Order Quantity | 1 Piece |
Display Type | Digital |
Weight | 50 g |
Environment | 0 to 50 deg C; RH max 95% |
Usage/Application | Measurement |
Model Name/Number | HI 98100 |
Brand | Hanna |
Range pH | 14.00 pH |
Resolution pH | 0.01 pH |
Accuracy pH | +-0.2 pH |
Dimensions | 50 x 174 x 21 mm |
Product Details:
Usage/Application | Measurement |
Brand | Hanna |
Weight | 1.2 kg (2.64 lbs.) |
Environment | 0 to 50 deg C (32 to 122 deg F; 273 to 323 K) RH max 95% non-condensing |
Dimensions | 160 X 231 X 94 mm |
Power Supply | 12 V DC Adapter |
Salinity Accuracy | +- 1% |
Salinity Range | 0.0 to 400.0% |
Resistivity Accuracy | +- 2% |
Temperature coefficient | 0.00 to 10.00 % deg C |
Reference Temperature | 5.0 to 30.0 deg C |
Product Details:
Usage/Application | Laboratory |
Weight | 250 g (8.82 oz) |
Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
Ph Range | -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode), +-1000 mV |
Temperature Accuracy | +-0.5 deg C, +-0.9 deg F |
Brand | Hanna |
pH Accuracy | +-0.2 mV, +-0.01 pH, +-0.002 pH |
Temperature Range | -20.0 to 120.0 deg C, -4.0 to 248.0 deg F |
Temperature Resolution | 0.1 deg C, 0.1 deg F |
Power Supply | 5 VDC adapter (included) |
Environment | 0 to 50 Degree C (32 to 122 Degree F), RH max 95% non-condensing |
Dimensions | 202 x 140 x 12 mm (7.9 x 5.5 x .05 Inch) |
Product Details:
Model Name/Number | PMP 450 |
Dimensions | Radio 27 X 21 X 7 cm (10.6 X 8.3 X 2.8 Inch), Antenna 51 X 13 X 7.3 cm (20.2 X 5.1 X 2.9 Inch) |
Maximum Power Consumption | 18 W |
Temperature | 40 deg C to +55 deg C (-40 deg F to +131 deg F) |
Wind Survival | 190 km/hour (118 mi/hour) |
Environmental | IP67 |
Weight | 5.9 kg (13 lbs) with antenna, 2.5 kg (5.5 lbs) without antenna |
Input Voltage | 24 to 30 V |